Custom UV & Ozone-Free Quartz Tubes
| Parameter | Typical Range |
|---|---|
| OD | 8–50 mm |
| Wall thickness | 1–4 mm |
| Length | Up to 3,000 mm |
| Material grade | Confirmed per application, sent with your quote |
| OH content | Confirmed per application |
| Transmission at key wavelength | Confirmed per application |
| UV cutoff wavelength | Confirmed per application |
| Ozone-generating / ozone-free designation | Set by the grade selected for your order |

Quartz Glass supplies quartz tubing selected by material grade for UV lamp and process applications — the grade determines how much UV actually reaches your target, and whether the tube generates ozone as a byproduct.
Dimensions above are typical for lamp and process tubing; material grade, OH content, and transmission figures depend on the specific quartz stock used and are confirmed against a real datasheet at quote time rather than quoted generically here.
Ozone-Generating vs. Ozone-Free Quartz Tubing
Quartz that transmits UV around 185 nm generates ozone, because that wavelength splits atmospheric oxygen. Quartz formulated to block roughly that region — while still passing 254 nm — is sold as ozone-free. Which one you need depends on the application: ozone-generating tubing is specified when ozone is the point (air or water treatment), and ozone-free is specified when it's a byproduct to avoid (most general germicidal or curing lamps in occupied or enclosed spaces).
Tell us which output you need — 185 nm, 254 nm, or both — and we'll confirm which grade applies.
UV Transmission, Cutoff Wavelength and Material Grade
OH content in the quartz is the main variable behind deep-UV transmission — generally, higher-OH synthetic material transmits further into the deep UV than lower-OH or natural quartz, though the exact cutoff depends on the specific melt and grade. Rather than publish a generic transmission curve here, Quartz Glass confirms cutoff wavelength and transmission at your operating wavelength against the actual material grade sourced for your order.
UV Quartz Tube Factory Standard & Manufacturing Limit
Material grade also limits which OD, wall, and length combinations are available — not every grade comes in every stock size, so grade and dimensions are confirmed together, not separately. See the table above for typical dimensional range; send your required wavelength and grade so we can confirm what applies.
Tube Diameter, Wall Thickness and Lamp Geometry
Tube OD and wall are usually set by the lamp or fixture the tube fits into, not chosen independently — confirm your lamp type or fixture drawing alongside the dimensions. End finishing for lamp tubes typically means fire-polished open ends or a pinch-sealed end for lamp assembly; tell us which your design needs.
Before shipment we check dimensions, wall thickness, appearance, end condition, and — where provided — material batch or grade documentation.
UV & Ozone-Free Tube Specifications
| Parameter | Reference Capability / Requirement |
|---|---|
| Material Grade | UV-transmitting JGS1-class or titanium-doped ozone-free quartz |
| Target Wavelength | 185 nm / 254 nm / application-specific UV band |
| 185 nm Requirement | Transmit for ozone-generating lamps or suppress for ozone-free operation |
| 254 nm Requirement | Maintain the germicidal output required by the lamp design |
| Reference OD | 8–60 mm for common lamp and sleeve formats |
| Reference Wall | 1–2 mm for common lamp formats |
| OD Tolerance | Reference ±0.3 mm |
| Length | 5–3,000 mm general fabrication envelope; specialty raw-tube availability may be narrower |
| Traceability | Finished dimensions linked to the selected UV material grade |
UV Lamp & Sleeve Reference Series
| OD Series | Wall | UV Function | Typical Equipment |
|---|---|---|---|
| Ø8 / 10 / 12 mm | 1 mm | 185 or 254 nm | Compact lamps and analytical sources |
| Ø15 / 18 / 20 mm | 1–1.5 mm | UV transmitting | Germicidal and photochemical lamps |
| Ø25 / 30 mm | 1.5–2 mm | Ozone-free option | UV curing and air-treatment systems |
| Ø35 / 40 mm | 1.5–2 mm | Grade selected | Protective lamp sleeves |
| Ø50 / 60 mm | 2 mm | Grade selected | Immersion sleeves and reactor envelopes |
| Custom formed tube | By drawing | Material-specific | Closed ends, flanges and welded assemblies |
Lamp-Tube Dimensional & Material Controls
| Feature | Size / Condition | Reference Tolerance |
|---|---|---|
| OD | 8–60 mm reference | ±0.3 mm |
| Wall Thickness | 1–2 mm reference | Tube-wall reference tolerance by size |
| Cut Length | Up to 3,000 mm | ±0.5 mm standard; ±0.1 mm precision where geometry permits |
| Straightness | Long lamp envelopes | Specified according to OD and finished length |
| 185 nm Behavior | Ozone / ozone-free | Verified by selected material grade |
| 254 nm Behavior | Germicidal output | Specified with the lamp requirement |
| Material Identity | Finished lot | Traceable to UV or titanium-doped raw tube |
UV Tube & Lamp-Envelope Configurations
UV-Transmitting & Ozone-Free Quartz Grades
OH content varies by grade and batch; the lot certificate is authoritative. Compare material routes and typical transmission data.
Cutting, Closing, Forming & Grade Traceability
- Material Selection185/254 nm function matched to the raw quartz grade
- Precision CuttingLamp and sleeve lengths produced to the assembly drawing
- End ClosingRounded or formed ends for immersion and protective sleeves
- Fire PolishingSmooth tube ends for assembly and handling
- Quartz WeldingPorts, flanges and extensions joined without mixing material identity
- Final VerificationDimensions and selected UV grade recorded for the finished component
UV & Ozone-Control Applications
Frequently Asked Questions
What is the difference between ozone-generating and ozone-free quartz?
Ozone-generating designs require transmission near 185 nm. Ozone-free titanium-doped quartz suppresses that region while retaining the required output around 254 nm.
Which dimensions are common for UV lamp tubes?
Reference lamp sizes use OD 8–60 mm and walls around 1–2 mm; the selected UV grade may have a narrower raw-tube range.
Can UV tubes be closed or made as immersion sleeves?
Yes. Tubes can be cut, closed, fire-polished, flanged or welded into protective sleeves and reactor assemblies.
How is the UV grade verified?
Material identity and wavelength requirement are specified with the order so the finished geometry remains traceable to the selected raw-tube grade.
Grade-Qualified Material Purity
Electric-fused / flame-fused quartz: SiO₂ ≥99.99%; synthetic JGS1-grade fused silica: ≥99.999%. Grade and lot certificate govern supplied material.
Formed Stock versus Cold-Cut Dimensions
Formed stock and finished cut parts use different length tolerances. Continuously drawn transparent stock: ±1.0 mm at OD ≤50 mm / ±2.0 mm at OD >50 mm. Rotationally fused opaque stock: ±5.0 mm. Cold-cut finished parts: standard ±0.5 mm; precision ±0.1 mm only where agreed for the finished geometry.
Customize This Product
Enter your dimensions of Custom UV & Ozone-Free Quartz Tubes — the technical drawing updates instantly, then request a quotation.
Every field is editable — drawing, weight estimate and part code update instantly.
Attached to your inquiry automatically when you press “Use This Configuration”.