Custom Quartz Cuvettes

Parameter Typical Range
Optical path length 1, 2, 5, or 10 mm (standard); custom on request
Internal width / height Matched to path length and target volume
Volume 0.5–4 mL, size-dependent
Window thickness 1–2 mm
Surface quality 60/40 to 40/20 Scratch-Dig
Flatness λ/4 @ 633 nm
Parallelism < 30 arcsec
Inquiry

Quartz cuvettes built around optical path length and window quality — the specs that actually determine measurement accuracy, not just internal volume.

Path length, window flatness, and parallelism define measurement accuracy together — a cuvette can be the right path length and still introduce error if the windows aren't parallel, since that changes the effective path length across the beam.

Optical Windows and Surface Requirements

Only the two windows in the optical path need the tightest flatness and parallelism spec — side walls not in the beam path can be functional-grade rather than optical-grade, which keeps cost down on larger or custom cuvettes. Surface quality (scratch-dig) matters most on the windows; scattered light from a scratched window shows up directly as measurement noise.

Quartz Cuvettes Factory Standard & Manufacturing Limit

Standard path lengths (1/2/5/10 mm) are the most repeatable without added lead time; custom path lengths are available but confirmed per order, since internal geometry has to be rebuilt around the new dimension, not just scaled. Parallelism is the figure most likely to need confirmation at the tightest end.

Quartz Cuvette Path Length and Cell Geometry

Internal chamber dimensions are set by path length and target sample volume together — a smaller sample volume at a fixed path length means a narrower internal width, which affects how much liquid is needed to fully cover the beam. Fabrication is precision plate cutting and polishing, then hot-welded or optically bonded into the cell body, with ports added where stirring or flow-through is needed. Before shipment we check path length, internal dimensions, window parallelism/surface, leak integrity, and overall form.

1 / 2 / 5 / 10 mmOptical Path Lengths
±0.01 mmPath Reference
10 × 10 mmCell Format
185 nmJGS1 UV Edge
FlowCell Option
JGS1 / JGS2Material Options
Optical Cell Definition

Path Length and Window Quality Are the Primary Cuvette Specifications

Controlled FeatureReference Capability / Requirement
Path Length1, 2, 5 or 10 mm reference series
Path Tolerance±0.01 mm industry-reference quotation level
Cell Format10 × 10 mm square, cylindrical or custom body
MaterialJGS1-class UV fused silica from 185 nm, or JGS2-class quartz by wavelength
Window SurfacePolished optical windows with the clear area defined
Window ParallelismSpecified where beam deviation or path accuracy requires control
ClosureOpen, capped, sealed or through-port configuration
Flow GeometryInlet, outlet, internal volume and orientation defined together
Cell Type Selection

Select the Optical Path Before the Closure and Ports

Cell TypeReference Path / FormTypical Measurement
Standard square1 / 2 / 5 / 10 mmUV-Vis absorbance
CylindricalCustom diameter and pathInstrument-specific holders
Fluorescence cellFour-window or defined viewing facesFluorescence spectroscopy
Flow-through cellPorts and chamber by drawingContinuous or inline detection
Available Forms

Configurations Defined by the Process

Standard CuvetteSquare optical cell with controlled path length
Sealed CuvetteClosed sample chamber with agreed fill method
Flow CellInlet and outlet integrated around the optical path
Cylindrical CellRound body matched to an instrument holder
Applications

UV-Vis, Fluorescence and Flow Detection

UV-Vis SpectroscopyJGS1-class cells specified from 185 nm when required
FluorescenceWindow arrangement matched to excitation and collection geometry
Flow DetectionSmall internal chamber with defined ports and path length
Custom InstrumentsCell envelope and optical center matched to the holder
Need a cuvette matched to an instrument?Send wavelength range, path length, holder envelope, clear windows, closure or port layout and sample compatibility.
Open the Product Configurator
Engineering Data

Grade-Qualified Material Purity

Electric-fused / flame-fused quartz: SiO₂ ≥99.99%; synthetic JGS1-grade fused silica: ≥99.999%. Grade and lot certificate govern supplied material.

Customize This Product

Enter your dimensions of Custom Quartz Cuvettes — the technical drawing updates instantly, then request a quotation.

Technical Drawing

Drawing redraws live · blue hatched area = cut section · all dimensions in mm
Parameters

Every field is editable — drawing, weight estimate and part code update instantly.

Common Options
pcs
Configuration Summary

Attached to your inquiry automatically when you press “Use This Configuration”.

—
REQUEST A QUOTE FOR QUARTZ GLASS PRODUCTS

    • Your Name (required)

    • Your Email (required)

    • Company Name (required)

    • Quantity (Optional)

    • Your Phone (Optional)

    • Product / Material (Optional)

    • Notes (required)

    • Drawing / Attachment (Optional)

    View all quartz products →